Find a Drayton stockist near you
Documents
Installation Guides
Brochures
User Guides
Specifications
- Part number
- 25039DR
- Energy Class (ErP rating)
- IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
- Relevant EC directives
- 2014/53/EU Radio Equipment Directive 2006/66/EC Batteries Directive 2011/65/EU RoHS Directive
- Applied standards
- EN60730-1; EN60730-2-7; EN60730-2-9 | EN 300 220-2; EN 301 489-3
- Software Class
- A
- Control accuracy
- ‹± 1 sec/day @ 25°C
- Timing resolution
- 1 minute
- Hot water and/or central heating programs
- 7 days
- Hot water pre-heat settings
- 3 ON/OFF
- Central heating settings
- 3 ON/OFF
- Ball pressure test
- 90°C
- Pollution degree
- 2
- Power supply
- 24Vd.c. less than 65mA 2xAA 1.5V alkaline batteries
- Battery life
- approx. 2 years
- Battery backup time & date
- 10 years min.
- Mounting
- Boiler mounted
- Wiring
- No wiring required
- Class of operation
- II
- Ambient operating temperature
- 0°C to +50°C
- Ambient operating humidity (non condensing)
- 30 - 95%
- Class of housing protection
- IP24