Specifications
- Energy Class
- IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
- Software Class
- A
- Relevant EC directives
- 2006/95/EC Low Voltage Directive | 2004/108/EC Electromagnetic Compatibility Directive | 1999/5/EC R&TTE Directive | 2013/56/EU Battery Directive | 2011/65/EU RoHS Directive
- Applied standards
- EN60730-1; EN60730-2-7; EN60730-2-9 | EN 300 220-2; EN 301 489-3
- Radio Signal Range
- 30m typically. The range may be affected by the compostion / density and number of wall between the thermostat and receiver
- Part number
- LP10RF & Digistat+3RF: RF561DR<br>LP10RF programmer (spare only): 22589DR<br>Digistat+3RF thermostat (spare only): 22092
- Setting range
- 5°C to 32°C
- Control accuracy
- LP10RF: ‹± 1 sec/day @ 25°C<br>Digistat+3RF: + 0.5°C @ 20°C
- Timing resolution
- 1 minute
- Hot water program type
- 7 day
- Central heating program type
- Flexible 5-2 day or 7 day
- Hot water pre-heat settings
- 3 ON / 3 OFF
- Central heating settings
- 6 per day
- Radio frequency
- 433 MHz
- Ball pressure test
- 90°C
- Pollution degree
- 2
- Power supply
- LP10RF: 24Vd.c. less than 65mA<br>Digistat+3RF: 2xAA 1.5V alkaline batteries
- Battery life
- approx. 2 years
- Battery back-up time and date
- 10 years min.
- Mounting
- LP10RF: Boiler mounted<br>Digistat+3RF: Suitable for surface mounting
- Wiring
- No wiring required
- Ambient operating temperature
- LP10RF: 0°C to +50°C<br>Digistat+3RF: 0°C to +40°C
- Ambient storage temperature
- –20°C to 55°C
- Ambient operating humidity (non condensing up to 45°C)
- LP10RF: 30 - 95%<br>Digistat+3RF: 25 - 90%
- Degree of housing protection
- LP10RF: IP24<br>Digistat+3RF: IP30