Find a Drayton stockist near you
Documents
Installation Guides
Specifications
- Relevant EC directives
- 2014/53/EU Radio Equipment Directive Batteries Directive 2006/66/EC, 2011/65/EU RoHS Directive
- Applied standards
- EN60730-1; EN60730-2-7; EN60730-2-9 | EN 300 220-2; EN 301 489-3
- Radio Signal Range
- 30m typically. The range may be affected by the compostion / density and number of wall between the thermostat and receiver
- Part number
- Digistat+C RF thermostat & SCR & sensor: 13616<br>SCR (spare only): 22598<br>Digistat+C RF thermostat (spare only): 13618<br>Sensor (spare only): 13619
- Setting range
- 40°C - 70°C
- Control accuracy
- +0/-8°C
- Temperature resolution
- 5°C
- Radio frequency
- 433 MHz
- Ball pressure test
- 75°C
- Pollution degree
- 2
- Power supply
- Digistat+C RF thermostat: 2 X 1.5V IEC LR6(AA) alkaline batteries<br>SCR (receiver): 230V a.c. 50Hz
- Battery life
- approx. 2 years
- Mounting
- Digistat+C RF: Suitable for surface or conduit box mounting<br>Sensor: Direct mounting onto water cylinder<br>SCR (receiver): Industry standard wall plate
- Wiring
- Designed for fixed wiring only, to comply with current IET wiring regulations (BS7671). Ø 0.5mm² 2 core cable between sensor and thermostat
- Switch type and rating
- SCR (receiver): S.P.D.T (volt free) 2(1)A 230V a.c. or 24V a.c./d.c
- Ambient operating temperature
- 0ºC to 50ºC
- Ambient storage temperature
- –20ºC to 55ºC
- Ambient operating humidity (non condensing)
- 25% to 90%
- Ambient storage humidity
- 15% - 95%
- Energy class
- IV = 2% (Acc. EU 811/2013, 812/2013, 813/2013, 814/2013)
- Software class
- A
- Degree of housing protection
- IP30