Find a Drayton stockist near you
Documents
Installation Guides
Specifications
- Part number
- 07 05 560
- Maximum Sensor Temperature
- 50
- Setting numbers
- 1 to 5 then “MAX”
- Temperature range
- 10-30ºC
- *Frost Protection
- Below 8ºC
- Sensitivity
- 0.22mm/°C
- Maximum flow temperature
- 110ºC
- Maximum static pressure
- 10 bar at 65ºC, 6 bar at 110ºC
- Maximum differential pressure
- 0.6 bar
- Hysteresis
- 0.4K
- Water temperature influence
- 0.8K
- Differential pressure influence
- 0.15K
- Response time
- 20 mins
- Control accuracy
- 0.6
Videos
Auto-balancing TRV launch
Dave Kempster on Auto-balancing TRVs
Related Products
TRV4 White
TRV4 Chrome