- Dimensions
- 161mm(w), 65mm(h), 30mm(d)
- Power supply
- 230 V AC ±10% 50Hz
- Switch rating
- 16A
- Wiring
- Fixed wiring only, to comply with current IET regulations (BS7671)
- Interfaces
- User: Push Button/LED
- Operating temperature
- 0°C to 50°C
- Storage temperature
- -20°C to 65°C
- Ingress protection
- IP 44
- Ambient humidity (non-condensing)
- Operating 25% to 90%, Storage 15% to 95%
- Ball pressure test
- 78°C
- Pollution degree
- 2
- Software class
- A
- Rated impulse voltage
- 4kV
- Radio technology/frequency
- 2.4GHz (Bi-directional, Mesh)
- Radio signal range
- 30m
- Mounting
- Independently mounted control
- Maximum radio frequency power transmitted
- +13dBm (25mW)
- Software version
- V1.0
- Relevant directives
- Radio Equipment Directives (RED) 2014/53/EU, RoHS directive 2011/65/EU and 2015/863/EU
- Applied standards
- EN60730-1; EN60730-2-9; EN 300 328; EN 301 489-1
- Sustainable offer status
- Green Premium product