- Part number
- 10mm Angled valve: 07 05 152<br>10mm Straight valve: 07 05 155<br>15mm Angled valve: 07 05 150<br>15mm Straight valve: 07 05 151
- Applied standards
- BS EN 215
- Temperature setting range
- Approx 10°C to 30°C
- Hysteresis
- 0.4K
- Water temperature influence
- 0.8K
- Differential pressure influence
- 0.15K
- Response time
- 20 minutes
- Energy efficiency rating
- Class I
- Setting numbers
- 1 to 5 then MAX
- Max. flow temperature
- 110°C
- Max. sensor temperature
- 50°C
- Frost protection
- Below 8°C
- Sensitivity
- 0.22mm/°C
- Control accuracy
- 0.6